Every commercial building needs regular Electrical Testing and Maintenance to stay safe and meet its legal duties. The essentials are a periodic EICR (fixed wiring inspection), planned preventative maintenance, PAT testing of appliances, and Emergency Lighting Installation & Testing. Commercial buildings are governed by the Electricity at Work Regulations 1989, which require all electrical systems in a workplace to be maintained in a safe condition. All of it should be handled by a qualified electrician.
Your electrics are the backbone of your business. When they fail, so does everything that depends on them: tills, machinery, lighting, heating and IT. Regular testing keeps that risk in check.
There’s a legal side too. Unlike rented homes, which fall under specific legislation, commercial buildings are governed by the Electricity at Work Regulations 1989, which mandates that all workplace electrical systems are maintained in a safe condition. In plain terms, if you run a business, keeping your electrical installations safe is your responsibility, not an optional extra.
Routine Electrical Testing Services protect you in three practical ways:
There’s also an insurance angle. Many policies now expect up-to-date electrical inspection records, and a missing or lapsed report can complicate a claim after an electrical incident.
Takeaway: Testing isn’t box-ticking; it’s how you keep people safe, stay compliant and keep the lights on.
An EICR (Electrical Installation Condition Report) is a formal assessment of your building’s fixed wiring. A qualified electrician examines the condition of the installation against BS 7671, the UK standard for the safety of electrical installations. It’s sometimes called fixed wire testing.
Every issue found is given a standard code. These codes are defined in BS 7671, and any report containing a C1, C2 or FI code is classified as “unsatisfactory.”
|
Code |
Meaning |
Action |
|
C1 |
Danger present |
Immediate risk of injury, may require immediate disconnection |
|
C2 |
Potentially dangerous |
Not immediately dangerous but could become so; remedial work required urgently |
|
C3 |
Improvement recommended |
Advisory only; the report can still be satisfactory |
|
FI |
Further investigation |
Makes the report unsatisfactory until investigated |
If your report comes back unsatisfactory, the listed remedial work must be completed before the installation can be considered safe. Glenfield’s team can carry out both the commercial EICR and any follow-up repairs.
An EICR tells you whether your fixed wiring is safe and exactly what needs fixing if it isn’t.
Electrical Inspection Services combine two things: a hands-on visual inspection and instrument-based testing. A qualified electrician works through the installation methodically.
A commercial inspection typically covers:
Alongside the fixed wiring, most businesses also need PAT testing, checking that electrical equipment (kettles, computers, power tools) is safe to use. Fixed wiring and portable appliances are separate jobs, and a thorough programme covers both. You can read more on Glenfield’s electrical testing and electrical inspection pages.
A proper inspection is a full check of your fixed wiring plus your appliances visual, dead and live testing combined.
An EICR is a snapshot. Planned maintenance is the ongoing care that keeps your electrical systems healthy between inspections and stops small faults becoming expensive ones.
Reactive repairs (waiting for something to break) are almost always more disruptive and costly than a planned programme. Preventative electrical maintenance helps by:
This is especially valuable in demanding environments warehouses, schools, offices and medical settings where a single fault can halt an entire operation. Glenfield offers tailored commercial electrical maintenance contracts, and there’s more detail in their guide on how often commercial properties should schedule maintenance.
Planned maintenance prevents the failures that reactive repairs only clean up after.
Emergency lighting keeps escape routes visible when the mains supply fails. In most non-domestic premises it’s a legal requirement, not a nice-to-have. It is required in virtually all non-domestic premises in the UK, including offices, shops, factories, warehouses, schools, hospitals, hotels and public buildings, with BS 5266-1 the primary British Standard governing its design, installation, testing and maintenance.
Installing it is only half the job. The system has to be proven regularly through two tests:
BS 5266-1 also requires a logbook recording every test, its date, results and any remedial action; fire safety inspectors will ask to see it. Fail to keep those records and you leave yourself exposed. Emergency Lighting Installation & Testing should be planned into your wider maintenance schedule, not treated as an afterthought.
Emergency lighting must be installed to BS 5266-1, tested monthly and annually, and logged or it can’t be relied on when it matters.
There’s no single legal interval for commercial EICRs. HSE guidance confirms there’s no mandatory test frequency, but systems must be maintained to prevent danger. Industry guidance based on BS 7671 gives sensible starting points:
|
Check |
Typical frequency |
Notes |
|
EICR / fixed wire test |
Every 5 years |
Or at change of occupancy; sooner for high-risk sites (heat, dust, moisture) |
|
PAT testing |
Risk-based |
Frequency depends on appliance type and environment |
|
Emergency lighting function |
Monthly |
Short flick test |
|
Emergency lighting full duration |
Annually |
Three-hour battery test |
Bring inspections forward if you change tenant or building use, add significant electrical load, or notice warning signs such as repeated tripping, flickering or a burning smell. For rented premises, a landlord’s duties can be stricter. Glenfield’s EICR frequency guide explains this in more detail.
Five years is the usual EICR starting point, but risk and usage decide the real schedule, and emergency lighting needs monthly and annual attention regardless.
All of this work EICR Testing & inspection, maintenance, fixed wiring checks, PAT testing and emergency lighting must be carried out by a competent, qualified electrician. Getting it wrong isn’t just a compliance risk; it’s a safety one.
Look for a contractor who is:
Glenfield Electrical is a NICEIC-approved contractor and Which? Trusted Trader offering the full range of commercial electrical services, backed by a five-year workmanship guarantee and “Phil’s Promise.” When you’re ready, you can book an electrician or get in touch for a free quote.
Only ever use a qualified, accredited electrician for both safety and compliance.
Reliable electrical work isn’t just about fixing faults; it’s about giving you peace of mind knowing your home or business is safe, efficient and future-ready. At Glenfield Electrical Ltd, our team of NICEIC-accredited domestic, commercial and industrial electricians delivers high-quality installations, inspections and maintenance you can trust, backed by clear communication and industry-beating guarantees. To get expert electrical support tailored to your needs, contact Glenfield Electrical Ltd at Unit 5, Mill Lane Industrial Estate, The Mill Lane, Glenfield, Leicester, LE3 8DX, United Kingdom. Call 0116 2873 226to request a quote and book your service today.